Skip to main content

CERTIFICATIONS

CERTIFICATIONS

A big company cannot be said to be such if it has not carried out the strictest reliability and durability tests on its products.

Our Industrial Group has started this process for many years, and for this reason, all projects are accompanied by certifications and markings issued by the most european countries as required by current regulations.
Our production engineers constantly monitor and improve the work cycles and can guarantee than the productions meet the project specifications and maintain the necessary quality required over time in accordance with the proof tests.


Designation CE

General information and CE designation of the flue chimneys

The certification IS MANDATORY!
Therefore, according to the EUROPEAN STANDARDS, the manufacturing companies must INDICATE THE PERFORMANCE of their products

  • UNI EN 1856-1: SINGLE WALL OR DOUBLE WALL FLUE PIPES SYSTEMS
  • UNI EN 1856-2: CONNECTION PIPES

THERE CANNOT BE ON THE MARKET UNMARKED FLUE PIPES


USE OF CERTIFIED products    ELIMINATES THE RESPONSIBILITY OF INSTALLERS to which it remains EXCLUSIVELY LIABILITY FOR ASSEMBLY

UNI EN 1856-1
Identifies the harmonized European standard that obliges manufacturers to perform certain tests to identify the performance of a chimney system.

A significant aspects of the CE mark IS OBLIGATION of the manufacturers to highlight LIMITS AND PERFORMANCE OF THE CHIMNEY

  • Temperature
  • Resistance to pressure
  • Resistance to condensation
  • Corrosion resistance of condensate
  • Technical speciations of the material
  • Resistance to soot fire
  • Distance from combustible materials

    EXAMPLE OF PRODUCT DESIGNATION

    EN 1856-1 T600 H1 W V2 L50040 G75

    EN 1856-1: Reference standard
    T600: IT IS THE TEMPERATURE LEVEL EXPRESSED IN CENTIGRADE DEGREES
    H1: IS THE GAS SEAL LEVEL – see table
    W: Identifies suitability for dry or wet operation
    “w = wet” – “d = dry”
    V2 : Corrosion resistance level, THE REGULATION DEFINES THE CORROSION RESISTANCE LEVEL
    L50040: L50 IDENTIFIES THE TYPE OF MATERIAL CONSTITUTING THE WALL IN CONTACT WITH THE SMOKES and
    040 identifies the thickness of the wall in contact with the fumes in tenths of a millimeter (040 = 0.4 mm = 4/10 mm).
    G75: IDENTIFIES SOOT RESISTANCE TO FIRE
    a chimney system that shows in the designation “O” IT IS TESTED FOR SOOT FIRE
    a chimney system that shows in the designation “G ” IT IS NOT TESTED FOR SOOT FIRE
    “75” indicates the distance in mm from combustible materials.